<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\CommandsStyleSheet.xsl"?>
<Command>
<Name>cal picker</Name>
<Description>
<DescriptionText><text>
This is a service command routine to semi automate setting up the following nvs
thresholds: val ssvth, val pvth, media x sst.
</text></DescriptionText>
<DescriptionText><text>
Cal picker may only be run from the monitor when there are no jobs in the system
and PrintConsole is shut down and an ale init has been done and the desired media
already set up in the current bay.  Cal Picker is a combined execution of cal pvth,
cal ssvth and cal sst.  Cal Picker will operate with minimal error checking.
</text></DescriptionText>
<DescriptionText><text>
First make sure that the current bay is properly loaded with the media and slipsheet
configuration that you want to calibrate for. (plate on top and slipsheet between each plate).
Check set state bay &lt;x&gt; sst  is 1 if slipsheets are loaded.
</text></DescriptionText>
<DescriptionText><text>
Cal Picker will open the cassette door and move the picker into the bay, take a
reading of the plate surface (for the picker slipsheet sensor), then lift the plate
and take a reading of the slipsheet between the plates. It will then grab the slipsheet
and take vacuum readings. Then it will transfer the plate to the picker vacuum cups
and take vacuum readings.   When it is done it will back out and leave the plate
untouched and save the new media X sst,   val pvth  and  val ssvth
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Syntax>
<NumberedList>
<ListItem><Text>
cal picker
</Text></ListItem>
<ListItem><Text>
cal pvth
</Text></ListItem>
<ListItem><Text>
cal sst
</Text></ListItem>
<ListItem><Text>
cal ssvth
</Text></ListItem>
</NumberedList>
</Syntax>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../commands/cal_pressure.xml</LinkAddress><LinkTitle>Command: cal pressure</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:38:48 2008 PST
</Updated>
<Links>
</Links>